Version 3 of the VMware Cloud Foundation 9.1.1 Fleet Latency Diagram is now available in the Broadcom VMware Ports and Protocols portal.
This is not a new VCF feature. It is a practical architecture reference for anyone designing, reviewing, or operating a VCF fleet across more than one site. The diagram maps the logical relationships between a primary and secondary VCF instance, VCF Operations, VCF Automation, management services, vCenter, SDDC Manager, NSX, and workload domains — including the latency limits that apply to the relevant paths.
The message is simple: do not treat every connection in a VCF design as if it has the same latency requirement. Fleet-level paths can allow up to 300 ms where indicated, but tighter limits apply to several management and control-plane interactions. The diagram also highlights limits for vCenter-to-SDDC Manager, NSX, vSphere Supervisor, long-distance vMotion, and vCenter Linking, as well as the minimum bandwidth callout for Edge deployments.
Most importantly, 300 ms is a supportability limit for specific paths — not a design target. A multi-site VCF design should still be engineered with margin and validated end to end for latency, packet loss, jitter, MTU, DNS, NTP, bandwidth, security controls, and failure behaviour.